Dataphysics dcat11

WebSep 23, 2016 · The adhesive forces of the lubricants on the AISI 52100 steel were measured using the high-sensitivity micro-electromechanical balance system (Dataphysics DCAT11, Germany) with the adhesive force mode as described in the Ref. . The procedures are as follows: Steel surface was placed on the testing table of the instrument, and the oil … WebThe interaction force between a water droplet and the MEF-derived ECM interface was assessed by a high-sensitivity microelectromechanical balance system (Dataphysics DCAT11, Germany), and the droplet contact angle was measured using the captive droplet method (Dataphysics OCA20). 23 The volume of the droplet was approximately 3 μL for …

Dataphysicsdataphysics表面张力仪(DCAT11)-参数-价格-仪器信 …

WebDCAT 11表面张力仪的技术参数:. 1、接触角测量范围:0~180° ; 分辨率±0. 01°. 2、表面界面张力的测量范围:1~1000mN/m; 精度±0. 001 mN/m. 3、密度的测量范 … WebSince August 1997, DataPhysics Instruments has been developing, manufacturing, and distributing laboratory measuring devices for the characterisation of interfaces and … flintstones software https://inkyoriginals.com

DCAT 21 - asi-team.com

http://www.asi-team.com/asi%20team/dataphysics/DataPhysics%20data/OCA10-20.pdf WebSEM images of (a) pristine cotton, (b) cotton-Br, (c) cotton-PGMA, and (d) cotton-PGMA-C 3 F 7 . Webbalance system in air environment (Dataphysics DCAT 11, Germany). A water droplet about 10 µL was suspended by a copper cap, and a hydrogel sample (1 by 1 by 0.5 cm3) was placed on the balance table, the table -moved upward at a constant speed of 0.005 mm s 1, until the underlying surface contacted the water droplet. Then the table was moved … greater than 0 criteria excel

Journal of Ma terials Chemistry A - Royal Society of Chemistry

Category:DataPhysics Instruments

Tags:Dataphysics dcat11

Dataphysics dcat11

Synthesis and Characterization of Lauryl Trimethyl ... - SpringerLink

WebThe DCAT 11 consists of the basic instrument with the following technical features: High-precision, electrodynamically compensated weighing system with automatic calibrating … http://www.pss.aus.net/index.php?option=com_content&view=article&id=58&Itemid=71

Dataphysics dcat11

Did you know?

WebMar 10, 2024 · Webinar Video: Vibration Data Acquisition to MATLAB with the Data Physics QUATTRO API. Last Updated on March 10, 2024 by dpnew Vibration Data Acquisition to … Web(Dataphysics, DCAT11) Liquid ≥ 200 ml. Phases > Air + sample 25 Critical Point Drying (CPD) Critical Poipont Drying (Leica, CPD300) Biological sample ≤ 1 gram 1 ml 0.5 x 0.5 cm . Sample preparation guidelines for analysis G-NN-IND-02 Rev.0 3 / 5 ...

WebApr 1, 2024 · Water contact angles (WCAs) were measured on a DataPhysics OCA 20 contact angle system at room temperature. The adhesive force was measured using a … Webelectromechanical balance system (Dataphysics DCAT11, Germany) with the adhesive force mode as described in the Ref. [29]. The procedures are as follows: Steel surface …

Webdataphysics dcat11 ( Brand: Dataphysics ), ( Manufacturer Part Number: DCAT11 ), ( Part Type: Tensiometer Instrument ), ( Country/region Of Manufacture: Germany ) Review … WebApr 1, 2024 · The average diameter of NPCM is from 200 to 500 nm. We also measure the dynamic viscosity at a shear rate of 100 rad/min by the rotary rheometer (HAAKE MARS II, German accuracy: ±0.001 kg/(m·s)), and surface tension by surface tension meter (Dataphysics DCAT11, German, accuracy: ±0.001mN/m), as shown in Table 1.

WebNov 10, 2024 · A density of ρ c = 1148.55 kg / m 3 at a temperature of 20 °C was measured with the density determination set DIS 11 (DCAT11, dataphysics, Filderstadt, Germany). The disperse phase consisted of a middle-chain triglyceride (MCT) Miglyol 812 ® (IOI Oleo GmbH, Witten, Germany).

greater than 0 in excelhttp://www.asi-team.com/asi%20team/dataphysics/DataPhysics%20data/DCAT21.pdf greater than 0 in python[email protected] • www.dataphysics.de Your sales partner: Technical information in this document is subject to change without prior notice. Errors and omissions excepted. … flintstones song wordshttp://www.laborexport.hu/_data/VFS_9282cd40482a5379c13c9cc3677d5868.pdf flintstones social climbersWebMay 13, 2009 · Aqueous solution equilibrium surface tension values were obtained by the Wilhelmy plate method using a Dataphysics tensiometer, model DCAT11. The CMC value was taken at the intersection of the linear portions of the plots of the surface tension against the logarithm of the surfactant concentration. Surfactant solutions were prepared with ... flintstones sofaWebJul 15, 2024 · The adhesive force was examined from a Dataphysics DCAT11 high-sensitivity micro-electromechanical balance system at three different places with a water droplet (ca. 4 µL). The electrochemical measurement was tested in a CS350 electrochemical workstation at 25 °C in several corrosive solution under open circuit conditions. Three … flintstones soft touchablesWebApr 13, 2024 · For the surface tension studies of the neat surfactant and polymer-surfactant (P/S) systems, a DCAT11 tensiometer from Dataphysics GmbH (Filderstadt, Germany) with a Pt-Y alloy Wilhelmy plate was used. The temperature was kept constant by using a thermostated Julabo F20 circulating water bath (Seelbach, Germany) set to 25.0 °C for … flintstones snacks